Exact-SKU research guide · 40914
UGREEN Nexode CD271 40914 200W 6-Port Desktop Charger
A six-output desk station built around two 100W USB-C laptop paths, two 65W USB-C paths and two conservative 10W USB-A accessory outputs.
Overview
UGREEN 40914 / CD271 is a six-port desktop charging station with four USB-C and two USB-A receptacles. USB-C1 and C2 can each provide up to 100W alone and are documented to charge two 100W-class devices together within the 200W total. USB-C3 and C4 can each reach 65W alone. The current official EU sheet describes USB-A1/A2 as 5V/2A, 10W each; because another official regional sheet lists higher profiles, this India draft uses 10W as the conservative planning figure until the physical label is checked. With more than two ports occupied, power remains dynamically shared within 200W.
Key features
Two 100W priority ports
Two 65W secondary ports
Thermal transparency
Port map and connector roles
USB-C1 / USB-C2
USB-C3 / USB-C4
USB-A1 / USB-A2
AC input
Exact power allocation
| System ceiling | 200W shared across all active outputs. |
|---|---|
| USB-C1 or C2 alone | Up to 100W each with a compatible device and 5A cable. |
| USB-C3 or C4 alone | Up to 65W each. |
| USB-A1 or A2 alone | Plan around 10W per the current official EU sheet/manual; check the India label because regional sheets conflict. |
| USB-C1 + USB-C2 | Documented 100W + 100W = 200W arrangement. |
| Three to six occupied outputs | Dynamically distributed within 200W; no unsupported fixed matrix is promised. |
| Thermal full-load control | The manual states that total output may temporarily reduce to about 165W at a preset upper temperature, then return to 200W after cooling. |
Charging protocols and speed logic
All four USB-C outputs support USB PD 3.0 and PPS within their individual voltage/current ranges, plus common QC/FCP/AFC/Apple/BC1.2 families. The USB-A outputs support common legacy quick-charge families, but official CD271 regional sheets disagree on their maximum electrical profile. This draft uses the lower 10W current-manual figure rather than overpromising 22.5W for India stock.
100W cable rule
PPS range
No PD 3.1 140W
Compatible devices and systems
Two USB-C laptops
65W devices
Phones and tablets
USB-A accessories
Use scenarios
Dual-laptop workstation
Editing or studio desk
Shared charging counter
Home office cable reduction
Setup and usability guidance
- Place the station on a stable, dry, ventilated surface with the ports and mains lead free of strain.
- Inspect the supplied mains cord and verify that its wall-end plug fits the intended socket securely. Do not promise or assume a regional adapter unless the exact India bundle lists one.
- Connect the detachable mains cord fully to the charger and wall supply before attaching devices.
- Start with the highest-demand laptop on the strongest documented USB-C port, using a suitable 5A cable where more than 60W is requested.
- Add other devices one at a time and use the verified allocation information instead of adding all single-port maxima together.
- Before a full-load session, place C1/C2 devices first and keep the housing clear so thermal management is not obstructed.
Everyday usability and care
Symmetrical pairs
Front-facing cable plan
Load changes
Thermal behaviour
Keep the desktop station on a hard surface, clean dust from around—not inside—the port openings, and avoid setting warm laptops or power banks directly on top of it.
What this product does
- Centralises several negotiated USB charging outputs around one detachable AC mains connection.
- Can power compatible laptops, tablets, phones and accessories when each device fits the relevant port profile.
- Dynamically shares a defined total power budget as connections change.
- Works as a standalone charger without software, drivers or network access.
- Provides a verified two-computer 100W + 100W arrangement.
What this product does not do
- It is not a dock, hub, display adapter, data switch, UPS or battery backup.
- The USB ports do not carry files, video, Ethernet or peripheral data.
- It does not guarantee that every port keeps its individual maximum during multi-device use.
- It cannot exceed the charging ceiling built into the device or cable.
- It does not contain six USB-C ports; two of the six outputs are USB-A.
What to do
- Use the labelled high-power USB-C ports for computers and reserve lower-power ports for phones or accessories.
- Use 5A e-marked USB-C cables for power above 60W and an EPR-rated cable when 28V PD 3.1 is required.
- Keep the station upright or flat as intended with clear ventilation around the housing.
- Allow the charger to renegotiate after adding or removing a device.
- Disconnect the mains cord before cleaning or rearranging the station.
- Verify the physical India label if more than 10W from either USB-A output is important.
What not to do
- Do not put the station under papers, fabric or other heat-trapping material.
- Do not use a damaged mains lead, loose wall socket or improvised plug connection.
- Do not treat a headline total as a single-port rating or add isolated maxima together.
- Do not place liquids, conductive objects or metal debris near the ports.
- Do not disassemble or continue operation after odour, arcing, repeated shutdown or visible damage.
- Do not use an undocumented six-port allocation chart copied from another UGREEN model.
Warnings and limitations
- The supplied mains-cord wall plug can vary by region; confirm the India pack physically when the live listing does not specify its wall end.
- High total output produces heat. Normal warmth should remain stable; abnormal heat or cycling is a stop-use condition.
- Adding or removing a device can briefly interrupt another output while the station assigns a new power budget.
- The strongest charging mode requires compatible device electronics and the correct cable, not merely a USB-C connector.
- The station is for dry indoor environments and does not provide battery backup during an outage.
- At sustained full load, the exact manual permits a temporary total reduction to about 165W for thermal control.
Troubleshooting
Two laptops are below 100W
USB-A rate differs from a listing
Total falls under prolonged heavy load
A device restarts when another is added
Technical specifications
| Brand / model / SKU | UGREEN Nexode CD271 / 40914 |
|---|---|
| AC input | 100–240V~ 50/60Hz, 2.5A max |
| Outputs | 4 × USB-C + 2 × USB-A |
| Maximum total | 200W shared |
| USB-C1 / C2 | Up to 100W each; fixed profiles through 20V/5A; PPS 3.3–21V/3A |
| USB-C3 / C4 | Up to 65W each; fixed profiles through 20V/3.25A; PPS 3.3–21V/3A |
| USB-A1 / A2 | Current official EU/manual: 5V/2A, 10W max each; other regional sheet: up to 22.5W |
| Verified dual-C allocation | C1 + C2: up to 100W + 100W |
| Thermal-control note | May temporarily reduce total to about 165W at preset full-load temperature |
| Dimensions | Approximately 101 × 101 × 32.3mm |
| Listed weight | Approximately 520g |
| Included AC cable | 2m detachable |
| Included USB-C cable | 1m USB-C to USB-C, rated up to 100W |
Package contents
Official exact-model materials list 1 × CD271 charger, 1 × 2m detachable AC power cable, 1 × 1m 100W USB-C to USB-C cable and 1 × user manual. The wall-end plug and an India adapter are not confirmed by the exact India page.
- Match SKU 40914 / CD271.
- Confirm the physical India label’s USB-A rating if it matters.
- Confirm the supplied mains-cord wall end or obtain a secure rated solution.
- Use C1+C2 for the verified dual-100W arrangement.