The charger works perfectly for my MacBook pro, samsung phone, iphone and samsung watch. All devices charged flawlessly. The charger is heavy and may fall when i place it in a socket on table. It heats up a bit but not too much.
Does the job perfectly.
Everything is great, Sound quality bulit quality, but while I on the device it say bluetooth on, while pairing its says bluetooth connected, this things make me awkward
Quality is good Plug n Play Works fine for Asus Rampage IV Black edition Motherboard as boot drive with WD 1 TB NVME Speed is 4700 Mbps Read N Write 3820 Mbps Fantastic Adapter Reviw it after 6 moth about durability
UGREEN Cat5/5e Unshielded RJ45 Plugs (50246) are 8P8C connectors for making and repairing your own Ethernet cables to exactly the length you need. 100 plugs per pack, with Gold-plated three-point contacts in clear housings so you can check the wiring.
100plugs per pack
Cat5/5erated
Clearhousing
Gold-platedcontacts
UGREEN Cat5/5e Unshielded RJ45 Plugs key features
Make custom-length cables Crimp onto bulk Ethernet cable.
You need a crimping tool. Crimp with an RJ45 crimper and test each cable with a network tester.
Use the same wiring standard (T568A or T568B) on both ends for a straight cable.
UGREEN Cat5/5e Unshielded RJ45 Plugs FAQs
Do I need a tool?
Yes, an RJ45 crimping tool.
How many plugs are in the pack?
100.
Which cable do they fit?
Cat5/5e cable.
Are they shielded?
No.
Can I make crossover cables?
Yes, wire one end T568A and the other T568B.
Genuine UGREEN, imported and sold by Sophus Technosol Pvt Ltd, the authorised national distributor. GST invoice with every order. 2-year India warranty.
UGREEN Cat5/5e Unshielded RJ45 Plugs (50246) are 8P8C connectors for making and repairing your own Ethernet cables to exactly the length you need. 100 plugs per pack, with Gold-plated three-point contacts in clear housings so you can check the wiring.
100plugs per pack
Cat5/5erated
Clearhousing
Gold-platedcontacts
UGREEN Cat5/5e Unshielded RJ45 Plugs key features
Make custom-length cables Crimp onto bulk Ethernet cable.
You need a crimping tool. Crimp with an RJ45 crimper and test each cable with a network tester.
Use the same wiring standard (T568A or T568B) on both ends for a straight cable.
UGREEN Cat5/5e Unshielded RJ45 Plugs FAQs
Do I need a tool?
Yes, an RJ45 crimping tool.
How many plugs are in the pack?
100.
Which cable do they fit?
Cat5/5e cable.
Are they shielded?
No.
Can I make crossover cables?
Yes, wire one end T568A and the other T568B.
Genuine UGREEN, imported and sold by Sophus Technosol Pvt Ltd, the authorised national distributor. GST invoice with every order. 2-year India warranty.
UGREEN 50246 is a bulk pack of 100 clear unshielded 8P8C modular plugs for terminating compatible Cat5 or Cat5e Ethernet cable. Each plug becomes a male modular cable end after correct conductor arrangement and crimping. It is a cable component, not an adapter or active network device. Below: selection, installation, compatibility, real limitations and safe use without treating a passive accessory as active networking equipment.
CAT5 / CAT5E • UNSHIELDED • 100 PACK
SKU 50246
ACTIVE product
CAT5 / CAT5E • UNSHIELDED • 100 PACK
Cat5 / Cat5eCable categories
8P8C male modular plugConnector
100Pack quantity
Clear plasticHousing
Features
What it does well.
Key features
Role. Each plug becomes a male modular cable end after correct conductor arrangement and crimping. It is a cable component, not an adapter or active network device.
Compatibility boundary. Compatible Cat5 and Cat5e UTP cable only after checking conductor diameter, solid/stranded construction and jacket geometry against the plug. Similar-looking modular plugs are not universally interchangeable.
Performance reality. The finished lead is limited by cable category and construction, conductor order, untwist length, crimp quality and connected network equipment.
Important exclusion. This is not a Cat6/Cat6A/Cat7/Cat8 guarantee, not shielded, not a pass-through plug, not a female coupler, not reusable after a failed crimp, and not a cable tester.
Where it fits in the connection
The system rule: every stage must match. The lowest-rated, damaged or incorrectly terminated component can limit speed, reliability, shielding, PoE operation or serviceability.
Scenario 2. Replacing a damaged plug on a cable whose conductor geometry fits.
Scenario 3. Bulk labelling and termination projects with repeatable test records.
Scenario 4. Keeping spare non-shielded plugs for controlled maintenance work.
Compatibility and selection guide
Use when. Compatible Cat5 and Cat5e UTP cable only after checking conductor diameter, solid/stranded construction and jacket geometry against the plug. Similar-looking modular plugs are not universally interchangeable.
Do not assume. not a Cat6/Cat6A/Cat7/Cat8 guarantee, not shielded, not a pass-through plug, not a female coupler, not reusable after a failed crimp, and not a cable tester. Before bulk purchase: trial the cable, module, plug or rack fit and complete one tested installation. Small physical differences can matter even within the same category name.
Setup and usability guidance
Work cleanly: dust, copper scraps and loose braid strands can create faults. Collect offcuts and inspect the finished area before energising connected equipment.
Step 1: Identify the cable category and verify it is unshielded Cat5/Cat5e with compatible conductors.
Step 2: Choose T568A or T568B and maintain the required scheme across the intended link.
Step 3: Strip the jacket carefully without nicking insulation; retain pair twists close to the plug.
Step 4: Order and flatten all eight conductors, trim evenly and insert fully into the clear housing.
Step 5: Confirm colour order and conductor reach visually before crimping.
Step 6: Crimp once with the correct 8P die, inspect strain capture and contacts, then test the finished cable.
Compatible devices and systems
Network endpoints. Routers, switches, access points, computers, printers, smart televisions, cameras and other RJ45 network equipment only through a correctly built compatible link.
Structured cabling. Wall outlets, patch panels, permanent cable and patch leads must share a suitable category, shielding design and wiring scheme.
PoE equipment. Possible only within the boundary: The listing does not provide a PoE class or current rating. Do not assume PoE suitability without a complete standards-compliant cable, connector and installation assessment.
Operating systems. No operating-system driver is required for this passive accessory or manual tool; active adapters and switches are separate products.
What this product does
Provides its documented function: Each plug becomes a male modular cable end after correct conductor arrangement and crimping. It is a cable component, not an adapter or active network device.
Supports the stated compatibility class: Compatible Cat5 and Cat5e UTP cable only after checking conductor diameter, solid/stranded construction and jacket geometry against the plug. Similar-looking modular plugs are not universally interchangeable.
Can form part of a serviceable labelled network: when installed with matched components and tested.
Keeps infrastructure modular: damaged or changed portions can be traced and replaced without rebuilding unrelated equipment.
Uses no software: this product is passive or manual and has no configuration app.
What this product does not do
It is not a Cat6/Cat6A/Cat7/Cat8 guarantee, not shielded, not a pass-through plug, not a female coupler, not reusable after a failed crimp, and not a cable tester.
It does not upgrade a lower-category cable or repair split pairs, poor conductor material, corrosion or bad device ports.
It does not guarantee PoE, bandwidth or error-free operation without a compliant complete link.
It does not remove the need for correct tools, installation practice, labelling and testing.
It should not be installed outdoors, in wet areas or beside mains wiring without a suitable compliant enclosure and qualified design.
What to do
Match. Match this SKU: use the title, construction and limits for 50246 rather than borrowing specifications from a similar family member.
Check. Check the complete path: confirm cable category, shielding, conductor construction, connector geometry, patch leads and endpoints.
Label. Label both ends: record room/port, wiring scheme and destination so later maintenance does not become guesswork.
Test. Test in stages: verify the cable or module before closing a wall plate or rack, then test again after final assembly.
Protect. Protect bend radius and strain relief: route cable gently and keep load away from contacts, IDC slots and device sockets.
What not to do
Do not force. Do not force parts: a keystone, plug, cable or tool that does not fit cleanly is probably the wrong geometry.
Do not miswire. Do not mix T568A and T568B accidentally: document the chosen scheme and check all eight conductors.
Do not over-untwist. Do not untwist pairs excessively: preserving pair geometry near termination matters to high-frequency performance.
Do not guess. Do not claim speed from appearance: clear housings, gold colour or a category marking do not replace complete-link testing.
Do not reuse damage. Do not use damaged parts: discard cracked housings, bent contacts, dull blades, loose shutters or failed crimp terminations.
Warnings and limitations
model limit: The finished lead is limited by cable category and construction, conductor order, untwist length, crimp quality and connected network equipment.
Sharp tools and contacts: keep fingers clear of blades, IDC contacts, trimmed conductors and crimp dies. Wear appropriate eye protection during cutting and termination.
Indoor low-voltage scope: no outdoor ingress rating is established. Keep the product dry, clean and away from corrosive environments or excessive heat.
Category is system-wide: a Cat5e, Cat6 or Cat7 label on one part does not upgrade the remaining cable, patch leads, terminations or equipment.
Test before service: visual inspection is not enough. Verify conductor map and real link negotiation; professional installations may require certification testing.
Do not work on live mains: networking hardware is low voltage, but wall boxes and racks may be close to hazardous electrical circuits.
Troubleshooting checklist
No link. Confirm both active devices, patch leads and port selections. Then check conductor map, full insertion and the connector/cable fit.
Lower speed than expected. Verify negotiation settings and every component category. Excessive untwist, split pairs and unsuitable cable construction can pass continuity yet fail performance.
Intermittent link. Look for incomplete seating, weak strain relief, damaged latch, nicked conductor, IDC not fully closed or a crimp made with the wrong die.
PoE device restarts. Stop use and inspect conductor material, gauge, contact engagement, heat and the powered equipment budget. Do not continue with a hot or damaged termination.
Shield or noise concern. For shielded products, check end-to-end shield design and grounding practice. Mixing shielded and unshielded parts can defeat the intended system.
Port or label mismatch. Trace one cable at a time, compare labels at both ends and update records immediately after correction.
model check before ordering
Match SKU 50246, product type, port or die count, cable category/construction and package contents. Similar UGREEN networking accessories can look nearly identical while using different shielding, conductor fit, rack format or termination method.
Specifications
At a glance.
Brand / SKU
UGREEN 50246
Product role
a bulk pack of 100 clear unshielded 8P8C modular plugs for terminating compatible Cat5 or Cat5e Ethernet cable
100 × UGREEN 50246 Cat5/Cat5e unshielded 8P8C modular plugs. Cable, boots, crimper and tester are not identified as included.
Devices, cables, racks, wall boxes, modules, tools and testers are not included unless explicitly named above.
FAQs
Questions buyers ask.
What exactly is UGREEN 50246?What is included in the package?Which cables, modules or devices are compatible?Does it guarantee the advertised network speed?Can it be used in a PoE network?Which tools are required?Does it split, switch, route or convert a network connection?How should a finished installation be tested?Is it suitable for outdoor or mains-power installation?What should I do if the link is intermittent?How is this SKU different from similar UGREEN products?