Namaste ! Vanakkam ! Namashkara ! Jai Jinendra ! India

Free Shipping for Normal Deliveries on orders above Rs. 999

Official Store • 2 Year Direct Warranty • GST invoice
Ugreen  |  SKU: 80452
50% off
New arrival

UGREEN 80452 Tool-Free Cat6 UTP RJ45 Keystone Jack, 180°

Sale price Rs. 277.00 Regular price Rs. 554.00
Tax included Shipping calculated at checkout.

Fast Connection
Secure Fit
High Speed
Easy Install
Reliable Link
CAT6 UTP • TOOL-FREE IDC • 180°

UGREEN 80452 Tool-Free Cat6 UTP RJ45 Keystone Jack, 180°

Overview

UGREEN 80452 is a tool-free Cat6 UTP keystone jack with an RJ45 female front and a rear IDC termination block. It terminates one compatible four-pair solid-installation cable into one female RJ45 outlet for a wall plate, patch position or other compatible keystone opening. This guide explains selection, installation, compatibility, real limitations and safe use without treating a passive accessory as active networking equipment.

Exact SKU 80452ACTIVE productCAT6 UTP • TOOL-FREE IDC • 180°
UGREEN 80452 exact product overview
UGREEN 80452 exact product overview
1

Key features

Exact role

It terminates one compatible four-pair solid-installation cable into one female RJ45 outlet for a wall plate, patch position or other compatible keystone opening.

Compatibility boundary

Unshielded Cat6 cable with listed 23–24AWG conductors, wired consistently to T568A or T568B. The module body must fit the selected keystone plate or panel, and the full link must meet the target category.

Performance reality

Listed for up to 1000Mbps and IEEE 802.3af/802.3at PoE when the complete channel, conductor material, pair geometry, termination quality and powered equipment are compliant.

Important exclusion

This is not a shielded Cat6A/Cat7 jack, not an RJ45 coupler with two female sockets, not a network switch, and not a substitute for cable certification or correct pair termination.

2

Where it fits in the connection

1. Network device
2. Patch lead
3. RJ45 front
4. IDC + cable
5. Patch panel / device

The system rule: every stage must match. The lowest-rated, damaged or incorrectly terminated component can limit speed, reliability, shielding, PoE operation or serviceability.

3

Use scenarios

Scenario 1

A Cat6 wall outlet in a compatible single- or dual-port faceplate.

Scenario 2

A labelled office or classroom structured-cabling run.

Scenario 3

A home-network position for a router, switch, access point, PC or smart television.

Scenario 4

A tool-free repair or new termination where the conductor and cable geometry match.

4

Compatibility and selection guide

Use when

Unshielded Cat6 cable with listed 23–24AWG conductors, wired consistently to T568A or T568B. The module body must fit the selected keystone plate or panel, and the full link must meet the target category.

Do not assume

not a shielded Cat6A/Cat7 jack, not an RJ45 coupler with two female sockets, not a network switch, and not a substitute for cable certification or correct pair termination.

Before bulk purchase: trial the exact cable, module, plug or rack fit and complete one tested installation. Small physical differences can matter even within the same category name.

UGREEN 80452 construction or installation detail
UGREEN 80452 construction or installation detail
5

Setup and usability guidance

  1. Step 1: Confirm Cat6 UTP construction and 23–24AWG conductor compatibility before stripping.
  2. Step 2: Choose either T568A or T568B and use the same scheme at both ends of the permanent link.
  3. Step 3: Open the transparent termination cap and preserve pair twists as close as practical to the IDC guides.
  4. Step 4: Place each conductor in the colour-coded channel; do not untwist or nick more cable than necessary.
  5. Step 5: Close the tool-free cap fully and verify that no bare conductor protrudes or pair is crossed.
  6. Step 6: Fit the jack into a compatible keystone opening, connect patch leads and test all eight conductors plus real link negotiation.

Work cleanly: dust, copper scraps and loose braid strands can create faults. Collect offcuts and inspect the finished area before energising connected equipment.

6

Compatible devices and systems

Network endpoints

Routers, switches, access points, computers, printers, smart televisions, cameras and other RJ45 network equipment only through a correctly built compatible link.

Structured cabling

Wall outlets, patch panels, permanent cable and patch leads must share a suitable category, shielding design and wiring scheme.

PoE equipment

Possible only within the verified boundary: Exact UGREEN India text lists IEEE 802.3af and 802.3at PoE. It does not establish a higher-power PoE tier or a particular current ceiling, so broader support must not be assumed.

Operating systems

No operating-system driver is required for this passive accessory or manual tool; active adapters and switches are separate products.

7

What this product does

  • Provides its exact documented function: It terminates one compatible four-pair solid-installation cable into one female RJ45 outlet for a wall plate, patch position or other compatible keystone opening.
  • Supports the stated compatibility class: Unshielded Cat6 cable with listed 23–24AWG conductors, wired consistently to T568A or T568B. The module body must fit the selected keystone plate or panel, and the full link must meet the target category.
  • Can form part of a serviceable labelled network: when installed with matched components and tested.
  • Keeps infrastructure modular: damaged or changed portions can be traced and replaced without rebuilding unrelated equipment.
  • Uses no software: this product is passive or manual and has no configuration app.
8

What this product does not do

  • It is not a shielded Cat6A/Cat7 jack, not an RJ45 coupler with two female sockets, not a network switch, and not a substitute for cable certification or correct pair termination.
  • It does not upgrade a lower-category cable or repair split pairs, poor conductor material, corrosion or bad device ports.
  • It does not guarantee PoE, bandwidth or error-free operation without a compliant complete link.
  • It does not remove the need for correct tools, installation practice, labelling and testing.
  • It should not be installed outdoors, in wet areas or beside mains wiring without a suitable compliant enclosure and qualified design.
9

What to do

Match

Match the exact SKU: use the title, construction and limits for 80452 rather than borrowing specifications from a similar family member.

Check

Check the complete path: confirm cable category, shielding, conductor construction, connector geometry, patch leads and endpoints.

Label

Label both ends: record room/port, wiring scheme and destination so later maintenance does not become guesswork.

Test

Test in stages: verify the cable or module before closing a wall plate or rack, then test again after final assembly.

Protect

Protect bend radius and strain relief: route cable gently and keep load away from contacts, IDC slots and device sockets.

10

What not to do

Do not force

Do not force parts: a keystone, plug, cable or tool that does not fit cleanly is probably the wrong geometry.

Do not miswire

Do not mix T568A and T568B accidentally: document the chosen scheme and check all eight conductors.

Do not over-untwist

Do not untwist pairs excessively: preserving pair geometry near termination matters to high-frequency performance.

Do not guess

Do not claim speed from appearance: clear housings, gold colour or a category marking do not replace complete-link testing.

Do not reuse damage

Do not use damaged parts: discard cracked housings, bent contacts, dull blades, loose shutters or failed crimp terminations.

11

Warnings and limitations

  • Sharp tools and contacts: keep fingers clear of blades, IDC contacts, trimmed conductors and crimp dies. Wear appropriate eye protection during cutting and termination.
  • Indoor low-voltage scope: no outdoor ingress rating is established. Keep the product dry, clean and away from corrosive environments or excessive heat.
  • Category is system-wide: a Cat5e, Cat6 or Cat7 label on one part does not upgrade the remaining cable, patch leads, terminations or equipment.
  • Test before service: visual inspection is not enough. Verify conductor map and real link negotiation; professional installations may require certification testing.
  • Do not work on live mains: networking hardware is low voltage, but wall boxes and racks may be close to hazardous electrical circuits.

Exact model limit: Listed for up to 1000Mbps and IEEE 802.3af/802.3at PoE when the complete channel, conductor material, pair geometry, termination quality and powered equipment are compliant.

12

Technical specifications

Brand / SKU UGREEN 80452
Product role a tool-free Cat6 UTP keystone jack with an RJ45 female front and a rear IDC termination block
Product type Tool-free Cat6 UTP keystone jack
Front interface 1 × RJ45 female, 8P8C
Rear interface Colour-coded IDC termination
Orientation 180° cable entry
Wiring schemes T568A and T568B
Listed conductor size 23–24AWG
Listed network rate Up to 1000Mbps with a compliant complete link
Listed PoE IEEE 802.3af / 802.3at
Contacts 50U gold-plated pins, as listed
Housing PC
Listed front head size 14.5 × 16mm
Verified source https://www.ugreenindia.com/products/ugreen-cat6-utp-tool-free-modular-connector-180-80452
13

Product research and claim reconciliation

Primary source: exact UGREEN India SKU page and the current live Shopify product record.

Visual check: Exact live images show the transparent tool-free cap, T568A/B colour map, 180° rear entry and Cat6 front marking. The published PoE shorthand is presented with the correct IEEE 802.3af/at names, while higher data-rate and higher-power tiers are deliberately left unclaimed.

Claim policy: conflicting family artwork, mistranslated metadata, impossible dimensions and adjacent-model specifications are excluded rather than averaged together.

UGREEN 80452 exact detail retained after conflict review
UGREEN 80452 exact detail retained after conflict review
14

Troubleshooting checklist

No link

Confirm both active devices, patch leads and port selections. Then check conductor map, full insertion and the exact connector/cable fit.

Lower speed than expected

Verify negotiation settings and every component category. Excessive untwist, split pairs and unsuitable cable construction can pass continuity yet fail performance.

Intermittent link

Look for incomplete seating, weak strain relief, damaged latch, nicked conductor, IDC not fully closed or a crimp made with the wrong die.

PoE device restarts

Stop use and inspect conductor material, gauge, contact engagement, heat and the powered equipment budget. Do not continue with a hot or damaged termination.

Shield or noise concern

For shielded products, check end-to-end shield design and grounding practice. Mixing shielded and unshielded parts can defeat the intended system.

Port or label mismatch

Trace one cable at a time, compare labels at both ends and update records immediately after correction.

15

Package contents

In the box

1 × UGREEN 80452 Cat6 UTP tool-free keystone jack. Wall plate, patch panel, cable, patch leads and test equipment are not identified as included.

Devices, cables, racks, wall boxes, modules, tools and testers are not included unless explicitly named above.

16

Product-specific FAQ

What exactly is UGREEN 80452?
A tool-free Cat6 UTP keystone jack with an RJ45 female front and a rear IDC termination block.
What is included in the package?
1 × UGREEN 80452 Cat6 UTP tool-free keystone jack. Wall plate, patch panel, cable, patch leads and test equipment are not identified as included.
Which cables, modules or devices are compatible?
Unshielded Cat6 cable with listed 23–24AWG conductors, wired consistently to T568A or T568B. The module body must fit the selected keystone plate or panel, and the full link must meet the target category.
Does it guarantee the advertised network speed?
Listed for up to 1000Mbps and IEEE 802.3af/802.3at PoE when the complete channel, conductor material, pair geometry, termination quality and powered equipment are compliant. Test the complete channel rather than judging one component in isolation.
Can it be used in a PoE network?
Exact UGREEN India text lists IEEE 802.3af and 802.3at PoE. It does not establish a higher-power PoE tier or a particular current ceiling, so broader support must not be assumed.
Which tools are required?
The rear closure is tool-free; a punch-down tool is not required for the documented termination method. A cable stripper, flush cutter and cable tester can still help prepare and verify the run.
Does it split, switch, route or convert a network connection?
No. not a shielded Cat6A/Cat7 jack, not an RJ45 coupler with two female sockets, not a network switch, and not a substitute for cable certification or correct pair termination. Any active switching, routing, conversion or power function requires separate purpose-built equipment.
How should a finished installation be tested?
Start with a wire-map or continuity test that checks all required conductors and shield where applicable. Then connect known-good equipment, confirm negotiated link speed and observe errors under normal traffic.
Is it suitable for outdoor or mains-power installation?
No outdoor or ingress-protection rating is verified. This is a low-voltage networking accessory; it is not a mains device. Follow separation, fire, grounding and building rules.
What should I do if the link is intermittent?
Remove power where applicable, inspect for partial insertion, wrong colour order, excessive untwist, nicked conductors, poor strain relief or an incompatible cable/connector fit. Reterminate only with matched parts, then test again.
How is this exact SKU different from similar UGREEN products?
Exact live images show the transparent tool-free cap, T568A/B colour map, 180° rear entry and Cat6 front marking. The published PoE shorthand is presented with the correct IEEE 802.3af/at names, while higher data-rate and higher-power tiers are deliberately left unclaimed.

Exact-model check before ordering

Match SKU 80452, product type, port or die count, cable category/construction and package contents. Similar UGREEN networking accessories can look nearly identical while using different shielding, conductor fit, rack format or termination method.

SKU 80452CAT6 UTP • TOOL-FREE IDC • 180°

GST Invoice available, just mail back with details to order confirmation mail.

Buy direct from official UGREEN India

GST Invoice, Warranty, authenticity, faster support